Application-first concrete fibre engineering[email protected] · WhatsApp +86 159 6543 3989
Cast / precast concrete

Wavy Macro Synthetic Fibre 48

Longitudinally wavy 100% virgin polypropylene macro fibre for cast and precast concrete; shotcrete requires a separate project trial.

48 mm · Virgin PP · Wavy profile
Wavy Macro Synthetic Fibre 48, longitudinally wavy polypropylene fibre

Application and selection

Wavy Macro Synthetic Fibre 48 is a white, flat macro synthetic fibre made from 100% virgin polypropylene with no added additives. Its longitudinal wavy profile provides an alternative mechanical anchorage geometry. It is intended for cast and precast concrete. Shotcrete use is a project-specific trial route, not a declared universal application.

Define the concrete process first

Confirm the required fibre role, mix, placement method, finishing or production cycle, and acceptance criteria before setting a dosage. The 4-8 kg/m³ manufacturer range is a starting point for project trials, not a predicted structural or post-crack result.

Batching and mixing

Determine the fibre dose by weight. For cast concrete, precast concrete or wet-mix trials, add unopened water-soluble collated units with the cement and aggregates during normal charging. After all fibre has entered the mixer, mix for a further 3-5 minutes or until uniform dispersion is confirmed. Validate the charging sequence, mixer loading and time in a representative plant trial.

Any shotcrete use, especially dry-mix use, needs separate qualification with the actual equipment and process. Review pumpability, spraying, rebound and the project-required acceptance method rather than transferring data from a different profile or mix.

Evidence boundary

Single-fibre values in the TDS are manufacturer specifications based on the same virgin-polypropylene raw material and drawing process used for High Strength 48. No product-specific independent third-party report is declared for this wavy profile. Residual strength and energy absorption are not declared. Verify project suitability through trial mixes, production trials and independent testing where required. No CE certification or accredited Conchip laboratory claim is made.

Return to the application

Related Solutions

A product page does not replace the engineering scene, process limits or project verification route.

Context-aware next step

Check this product against the real project.

Send the application, process, mix, equipment, required evidence, quantity and destination. The inquiry keeps this product context.